2 fault areas and their types in order of severity – JLG TF6-42 Service Manual Manuale d'uso
Pagina 204

15
2.2.14 Overview of Fault Codes
2.2.14.1 Overview of Fault Types
TYPE
Comment
SHORT
.00 the output or input is shorted (or pulled too low)
OPEN
.01 the output or input is unconnected (or pulled too high)
OVERCURRENT
.02 there is an over current condition on the output
OOR
.03 the output current is Out Of Range
TOO_LOW
.04 the fault source has a too low value
TOO_HIGH
.05 the fault source has a too high value
INVALID_PATT
.06 an invalid pattern is detected
ERR_SHDN_BRAKE
.10 SHUTDOWN is caused by a problem related to the brake
ERR_SHDN_OUTPUT
.11 SHUTDOWN is caused by a problem related to an output
ERR_SHDN_SPEED
.12 SHUTDOWN is caused by a problem related to a speed
sensor
ERR_SHDN_XMSN
.13 SHUTDOWN is caused by a problem related to the
transmission
ERR_SHDN_OTHER
.14 SHUTDOWN is caused by another problem
IRAM_FAULT
.50 internal RAM fault
SRAM_FAULT
.51 internal system RAM fault
ERAM_FAULT
.52 external RAM fault
CROM_FAULT
.53 FLASH ROM checksum fault
RTST
.98 There is a runtime self test fault detected
2.2.14.2 Fault Areas and Their Types in Order of Severity
Fault
Fault area
Fault Types
Battery Voltage
30
04, 05
Power On Self Test
00
50, 51, 52, 53
Over Current
21
03
Shut Down
42
10,11,12,13,14
Digital output 0
Parking brake solenoid
80
00, 01
Analog Output 0
Brake solenoid
70
00, 01, 02, 03
Speed Sensor Supply voltage
31
04, 05
Drum speed (A24 – A25)
61
00, 01
Digital output 1
Forward solenoid
81
00, 01
Digital output 2
Reverse solenoid
82
00, 01