In the following error cases: probe malfunction, chamber probe
malfunction, cycle interrupted because the door was open for
too long, cycle interrupted because of lack of voltage, cycle
interrupted because of a hardware anomaly, cycle interrupted
prematurely by the user, icon no. 16 flashes; in all these
cases the food CANNOT be used.
Call the Service Centre if the defect cannot be eliminated.
During a programmed cycle, if the door remains open for less
than 15 seconds a buzzer sounds and icons no. 07/08/14/15
flash in order; the cycle is not interrupted, and so by closing
the door, the cycle restarts immediately. If the door should
remain open for between 15 seconds and 3 minutes, the cycle
is paused; icons no. 07/08/14/15 flash in order; when the door
is closed, the cycle starts again from where it was interrupted.
If the door should remain open for more than 3 minutes, the
cycle is definitively interrupted and the appliance goes into the
alarm state.
If there should be an interruption in the voltage for less than 3
minutes, the appliance will start the chosen cycle again
autonomously, once the mains power is restored.
During a programmed cycle, if the voltage should be
interrupted for more than 3 minutes, the cycle will also be
interrupted and the appliance will go into an alarm state; in
order to restart the appliance, in this case, it is necessary to
carry out a reset (pressing buttons 1 and 6 at the same time
for a few seconds until a double buzzer is heard).
During a programmed cycle, if low yield conditions should
occur, it is always advisable NOT to consume the product. The
low yield could either be caused by an error in selecting the
class of products to be chill blasted or deep-frozen or by
putting too much food into the appliance at one time. If the
appliance repeatedly signals low yield conditions without it
being due to one of the previously listed causes, we strongly
suggest that you contact a Service Centre in order to resolve
the problem.
During a programmed cycle, if a malfunction should occur with
the chamber probe, none of the cycles can be started; if there
is a cycle in progress it will be interrupted and the appliance
will go into alarm state. Icon no. 14 will flash with the
appliance switched on until the problem is solved.
During a programmed cycle, if there should be a malfunction
with the food probe, it will not be possible to start the cycles
which use the food probe; if there is a cycle in progress it will
be interrupted and the appliance will go into alarm state.
26