NOTE FOR THE FITTER

After having positioned and connected the blast chiller, the

technical personnel must check that it has been installed

correctly.

By checking that the electrical connection is functioning

correctly.

By checking that the command and control systems are

functioning.

By checking that the fan is not blocked.

By carrying out at least one complete dry-run cycle to check

that all the components of the appliance are working perfectly.

By cleaning the inside of the appliance before using it.

Test mode: with the blast chiller switched off, press buttons 1

and 3 at the same time, then 1 and 5; if no button is pressed,

after 5 seconds the system exits the test mode.

In the test mode:

- button 1 activates the compressor and switches on icon 10.

- button 2 activates the condenser fan and switches on icon

11.

- button 3 activates the evaporator fan and switches on icon

12.

If the door is open, icon 7 is activated.

If the chamber probe is malfunctioning, icon 4 is activated.

If the food probe is malfunctioning, icon 9 is activated.