Pay attention as to how the drip-tray is positioned.
6.11 BREAKDOWN ALARM
If the appliance is blocked by one or more causes, the system
will go into alarm state and icons no.
07/08/09/10/11/12/13/14/15/16 will all flash at the same
time; when any of the alarm buttons is pressed, only one of
the icons will continue flashing, thus indicating the cause of the
alarm. Only in the case of a low yield signal will the appliance
give an indication of the problem, but the cycle and any
maintenance period will, however, be brought to an end by
implementing the alarm state only at the end of the cycle.
Interruption due to the door being open: lights up icon no. 15
Interruption due to lack of voltage: lights up icon no. 16.
Interruption due to voluntary cycle interruption: lights up icon
no. 13.
Interruption due to low yield: lights up icon no. 8.
Interruption due to chamber probe malfunction: lights up icon
no. 14.
Interruption due to core probe malfunction: lights up icon no. 9
The alarm state is cancelled by pressing down buttons 1 and 6
for a few seconds until a double buzzer is heard; the icons will
stop flashing and the appliance should be programmed again.
The same operation should be carried out if the appliance is
blocked by a voluntary interruption of a cycle before its
programmed end.
Figure 8
25