MNVADCJ01_0543
•
If the set of accepted cameras is to be defined more precisely (some cameras in the set should be accepted
and others not), press
to subdivide the set shown into smaller sets.
•
press
to return to the previous display menus.
The following example shows how to accept cameras 1 to 7, and at the same time disable access to all the
others. To camera 3 is assigned receiver 12 connected to telemetry line B::
k(0PCOCa
(0PCCOb
(0PCOb
All cameras in the 1-1000 set are accepted, while those from
1001 to 3000 are not. Select the 1-1000 set with the joystick
2
and press
*
to completely disable all cameras.
k(0PCOCb
(0PCCOb
(0PCOb
The icons on the right of the display show that none of the
cameras in the sets from 1 to 3000 are now available on request.
Select the 1-1000 set with the joystick
2
and press
to pass
to a more precise definition level.
k(0PCOCb
(0PCCOb
(0PCOb
The sets shown on the display are now of 100 cameras each.
None of the cameras in the sets are accepted.
Select the 1-100 set with
2
and press
to pass to a more
precise definition level.
k(0PCOCa
(0PCCOb
(0PCOb
Select the 1-10 set and press
!
to accept all cameras in the
set from 1 to 10.
Then press
to define acceptance at the individual camera level.
PPPRP
kC,6C
,6
,6
The menu changes to allow precise definition of the individual
cameras.
Given that all cameras from 1 to 10 are now accepted, it is
necessary to scroll the list with the joystick to disable cameras
8,9,10, as required in the example.
Scroll the list with
2
until camera 8 is reached.
PPPRP
#,6#
k$,6$
%,6%
The heading on the first line means:
•
: camera number
•
: the camera can or cannot be selected from the
keyboard
•
: number of receiver/dome assigned to the camera
R
: control line (A or B) for the receiver/dome
Press
*
to disable camera 8. Disabling the camera will
automatically remove the receiver number and the corresponding
telemetry line.