En g l is h – Clay Paky SHADOW Manuale d'uso
Pagina 11

TECHNICAL DATA
10
ELECTRICAL
MECHANICAL SPECIFICATIONS
Power supply
• 220 - 240V 50Hz
• 200 - 220V 60Hz
Lamp
Metal halide with special built-in power
supply.
• Type: HMI 1200W
- Cap: SFc 15.5-6
- Colour temperature: 6000 K
- Luminous flux: 110000 lm
- Average life: 750 h
• Type: HMI 575W
- Cap: SFc 10-4
- Colour temperature: 6000 K
- Luminous flux: 49000 lm
- Average life: 750 h
Power consumption
• QS-ST/LT HMI 1200:
1500VA at 230V 50Hz
• BASIC HMI 1200:
3000VA at 230V 50Hz
• BASIC HMI 575:
1500VA at 230V 50Hz
Motors
N. 4 (BASIC) N. 5 (QS) microstepping
motors with full microprocessor control.
OPTICAL SYSTEM
Main optical unit
• Base in diecast aluminium.
• Twin lens condenser.
• High luminous efficiency spherical
reflector.
Lens unit
QS-ST and BASIC
• Standard: 1:2.5/250mm
• Optional: wide angle for insertion
inside the projector.
QS-LT
Special optics with wide angle lens as
standard (manual insertion).
CONTROL SYSTEMS
Channels
N. 3 control channels (BASIC)
N. 4 control channels (QS)
Inputs
SHADOW QS is set up to accept analog
or digital signals from controllers or
computers:
• Digital serial input
RS232/423(PMX) or DMX512
• 0-10V analog input
CONSTRUCTION
FEATURES
Safety devices
• Power shuts off automatically in the
event of overheating or cooling system
failure.
• Power shuts off automatically when
cover is opened.
Cooling
Forced ventilation cooling system using
axial flow fans.
Housing
• Extruded diecast aluminium.
• Epoxy powder coated finish.
Mounting
• Steel bracket with epoxy powder coat-
ed finish.
• Six installation positions, 25 mm
apart.
• Bracket adjustable through 100° with
graduated scale for position finding.
Operating position
Will function in any position.
Weights and Dimensions
• QS-ST HMI 1200: 38 kg ( 83 lbs 10 ozs)
• QS-LT HMI 1200: 49 kg (107 lbs 13 ozs)
• Basic HMI 1200: 38 kg ( 83 lbs 10 ozs)
• Basic HMI 575:
30 kg ( 66 lbs)
(67.5”)
1715
(17.1”)
435
(13”
√17.5”)
330
√445
(17.1”)
435
(13”
√17.5”)
330
√445
(46.3”)
1175
SHADOW Basic HMI 575
SHADOW Basic HMI 1200
SHADOW QS ST HMI 1200
SHADOW QS-LT HMI 1200
E
N
G
L
IS
H
11
IMPORTANT: do not use solvents or alcohol
Parts that need cleaning frequently.
Parts that need cleaning monthly.
Internal components should also be given a general clean once a year, dislodging
dust and dirt with a brush and removing it simultaneously with a vacuum cleaner.
• Routine cleaning
To maintain the light output of the projector undiminished, parts that tend to accu-
mulate dust and grease must be cleaned periodically.
In most circumstances, the projector will give long and trouble-free service if these
simple guidelines are followed.
To remove dirt from the lenses and filters, use a soft cloth moistened with any liq-
uid detergent suitable for cleaning glass.
TROUBLESHOOTING
9
No electrical power supply.
Check that power is available at the
mains socket.
ELECTRONICS NOT WORKING
PROJECTOR DOES NOT LIGHT UP
PROJECTION FAULTY FAULTS
ANOMALIES
REDUCED BRIGHTNESS
POSSIBLE CAUSES
CHECKS AND REMEDIES
•
•
•
•
•
•
•
• •
Lamp expended or faulty.
Change lamp (see instructions).
Signal transmission cable short-
circuiting or disconnected.
Change cables.
Address codes incorrect.
See projector coding instructions.
Defect in electronic circuits.
Contact an authorized technician.
Lenses broken.
Contact an authorized technician.
Deposit of dust or grease.
Clean (see instructions).