Introduction, Description, Features – Proel WCS1000RX Manuale d'uso
Pagina 6: Wcs1000 receiver unit

6
INTRODUCTION
Thank you for choosing this PROEL product and for your trust in our brand, synonymous of professionalism,
accuracy, high quality and reliability. All our products are CE approved and designed for continuous use in
professional systems.
DESCRIPTION
The WCS1000 Wireless Conference System provides advanced technology, ease of use and flexibility in a full
modular setup. WCS1000 system offers reliability, intuitive operation and versatility: it can be perfectly
integrated into any meeting rooms without additional wiring and it’s the ideal choice for mobile conference
systems or for small-to-medium scale fixed systems
WCS1000 system features 5 units:
•
WCS1000RX wireless system receiver unit.
•
WCS1000C chairman transmitter unit.
•
WCS1000D delegate transmitter unit.
•
WCS1000CH battery charger for 16 Li-Ion battery packs.
•
IRC14430X3 Li-Ion battery pack (to supply the WCS1000C and WCS1000D units).
Each system can handle up to 256 WCS1000D delegate units (with up to 4 units that can be used
simultaneously) plus one WCS1000C chairman unit.
FEATURES
Up to 256 wireless microphone units in one system, 5 microphone units (1 chairman, 4 delegates)
can be turned on at the same time.
Operating Modes: LIMIT 1-4, FIFO 1-4, Chairman Only.
Microphone units operates with Li-Ion rechargeable batteries, for approximately 8 hours of
continuous speech or 30 hours in standby.
Wireless communication system eliminates the need of wired connections, so the installation can be
done easily and quickly without cumbersome arrangements.
Multi-channel high UHF band and intermediate UHF band frequency selective filtering able to
eliminate RF interference signal.
Acoustic feedback eliminating technology for reducing the ricks of feedbacks from the loudspeakers.
Multiple noise detecting circuit and TONE-LOCK system for a strong anti-jamming function.
Free open space operation distance up to 100 meters, 60 meters are usually guaranteed in typical
closed environment.
WCS1000 RECEIVER UNIT
See FIG. 1 at page 37.
1.
POWER
On/off switch: press and hold for two seconds to switch on or off the receiver.
2.
RF / AUDIO LEVEL INDICATORS
The first channel (C) is for chairman microphone, the following four channels (D1, D2, D3, D4) are for
delegate microphones. On each LED bar the first green LED indicates that the receiver is receiving a radio
signal from a transmitter unit on that channel. If the LED is off, check if the transmitter is off or set as
ready or set for another RM (see ROOM function further). The red LEDs show the audio signal level from
the microphone unit.
TIP, HOW TO SET THE OPTIMAL LEVELS: to set the optimal level for each transmitter follow in
sequence these instructions.
a) Set the VOL knob of the channel at minimum.