PRELIMINARY

Channel Mode

DMX

Value

Function

Standard Independent

GREEN RATE

0 - 5

Light OFF

6 - 255

Flashing at linearly variable frequency from low:

(~0.3 flashes/sec or 1 flash every period of 3.5sec)

to high (25 flashes/sec or 1°flash every period of 40msec)

See details in a following dedicated table.
BLUE INTENSITY

0 - 255

Blue colour linearly increase from no-light to maximum intensity
BLUE DURATION

0 - 255

Light time (versus dark time) linearly increases from shorter time

(2.5msec) to longer time (650msec)

See details in a following dedicated table.

IMPORTANT:

Duration Time must be lower than Rate Time (Period) for flashing.

If Duration Time is equal or greater than Rate Time (Period) the light

is continuously on.
BLUE RATE

0 - 5

Light OFF

6 - 255

Flashing at linearly variable frequency from low:

(~0.3 flashes/sec or 1 flash every period of 3.5sec)

to high (25 flashes/sec or 1°flash every period of 40msec)

See details in a following dedicated table.
WHITE INTENSITY

0 - 255

Blue colour linearly increase from no-light to maximum intensity
WHITE DURATION

0 - 255

Light time (versus dark time) linearly increases from shorter time

(2.5msec) to longer time (650msec)

See details in a following dedicated table.

IMPORTANT:

Duration Time must be lower than Rate Time (Period) for flashing.

If Duration Time is equal or greater than Rate Time (Period) the light

is continuously on.
WHITE RATE

0 - 5

Light OFF

6 - 255

Flashing at linearly variable frequency from low:

(~0.3 flashes/sec or 1 flash every period of 3.5sec)

to high (25 flashes/sec or 1°flash every period of 40msec)

See details in a following dedicated table.
MASTER INTENSITY

0 - 5

No Light output

6 - 255

Light output linearly increase from minimum to maximum brightness
DURATION

0 - 255

Light time (versus dark time) linearly increases from shorter time

(2.5msec) to longer time (650msec)

See details in a following dedicated table.

IMPORTANT:

Duration Time must be lower than Rate Time (Period) for flashing.

If Duration Time is equal or greater than Rate Time (Period) the light

is continuously on.

STORMY CC C71091

CHANNELS

Continua

Advertising
Questo manuale è associato alle seguenti prodotti: