11 - TROUBLE SHOOTING

PROBLEM

CAUSE

REMEDY

Machine switch off

1. Mains switch off

1. position the machine switch to position ON

2. Machine switch off

2. position the machine switch to position 1

3. Incorrect electrical mains connection

3. contact specialized personnel in order

to check the connection

No water in boiler

1. Mains tap closed

1. open the mains tap

2. Clogged pump filter

2. replace the filter

3. Motor driven pump not in operation

3. contact specialized personnel

No unit delivery

1. mains tap closed

1. open the mains tap

2. motor driven pump out of order

2. contact specialized personnel

3. clogged gigleur

3. contact specialized personnel

4. burnt control box fuse

4. contact specialized personnel

5. unit solenoid valve out of order

5. contact specialized personnel

6. unit switch out of order

6. contact specialized personnel

Steam fails to come out of

the nozzle

1. too much water in boiler

1. see specific problem

2. damaged resistance

2. contact specialized personnel

3. clogged sprayer element

3. clean the sprayer element

4. resistance saver engaged

4. reinsert the resistance

Too much water in the boiler

1. the motor driven pump remains

engaged

1. contact specialized personnel

2. perforated exchanger

2. contact specialized personnel

3. automatic charge solenoid valve

blocked

3. contact specialized personnel

Signs of water leakage on

bench

1. dirty drain tray

1. clean the try

2. drainage pipe clogged or detached

2. replace the drainage pipe

3. other leakage

3. contact specialized personnel

Wet coffee dregs

1. Grinding regulated too fine

1. Adjust grinding value

2. Unit still cold

2. wait for the machine to reach the

correct temperature

3. Solenoid valve fails to discharge

3. contact specialized personnel

Coffee dispensing too slow

1. grinding element set too fine

1. Adjust the grinder

2. dirty filter-holder

2. replace the filter and undertake more

frequent filter-holder cleaning

3. clogged unit

3. contact specialized personnel

4. gigleur or solenoid valve partially

clogged

4. contact specialized personnel

Coffee dispensing too fast

1. grinder is regulated too large

1. regulate the grinding

Coffee delivered cold

1. Lime scale present on the exchangers

or the resistances

1. contact specialized personnel

2. oxidized pressure switch contacts

2. contact specialized personnel

3. defective electrical connection

3. contact specialized personnel

4. partially burnt out resistance

4. replace the resistance element

Coffee delivered too hot

1. incorrect pressure switch calibration

1. regulate the pressure switch by means

of the relative screw (chap. 6.2)

12 - MACHINE DISMANTLING

To dismantle the machine we recommend that it is dismantled and
the parts separated according to the type of materials involved
(plastic, metal, etc). The parts separated in this way are then to be
sent to the relative specialized disposal companies.

Advertising