Pre ven tive main te nance. 22, Fill ing the cool ant res er voir. 23, Preventive maintenance – Bird Technologies 6091P Manuale d'uso
Pagina 33: Filling the coolant reservoir
Advertising

21
Maintenance
MODEL 6091/6091P CALORIMETER PERFORMANCE TEST RECORD
Calorimeter Unit Serial Number:
MAXIMUM VSWR
Frequency Range
Maximum
VSWR
Acceptable
Limit (max)
300 kHz to 1000 MHz
1.10
1000 MHZ to 2500 MHZ
1.25
POWER MEASUREMENT ACCURACY
Volts
RMS
Nominal
Power
Power Meter
Reading
Minimum
Acceptance
Limit
1
Calorimeter
RF Power
Reading
Maximum
Acceptance
Limit
2
Allowable
Error
22.4
10 watts
±3.0%
35.4
25 watts
±1.25%
70.7
100 watts
±1.25%
100.0
200 watts
±1.25%
1
Subtract allowable error from power meter reading to find minimum acceptance limit.
2
Add allowable error to power meter reading to find maximum acceptance limit.
COMMENTS:
Tested by:
Date:
Advertising
Questo manuale è associato alle seguenti prodotti: