Schema idraulico HSM Modello 293.32

Informazioni prodotto HSM Modello 293.32

Introduzione

17

Schema idraulico HSM Modello 293.32

-06

-32

-06

-32

-32

-32

HB 2

-06

-08

-32

-06

25 µm

-06

50 psi

D

P

35 psi

3 µm

-32

HB 1

-06

-06

-06

Pilot Pressure Filter

switch

Check Valve

Pilot Pressure
Accumulator

Pilot Pressure Out

Pressure Out

Pressure Out

Return In

Filter Drain
Only

Main Filter

CONTROL MANIFOLD

Main Control Valve

Slow Turn-On
Accumulator (500 psi
precharge)

SOL 1

ON/OFF

solenoid valve

(low press on)

SOL 2
HI/LOW
solenoid valve
(hi press on)

Inlet Check
Valve

Pressure In

Return

Accumulator

Return Out

Return In

Pilot Return In

Drain In

Drain In

Drain In

Drain Out

Low
pressure
adjust

Pressure
Accumulator

Pressure
Gage