Fast & Fluid LEOLUX NV Manuale d'uso
Pagina 21

FAST & FLUID MANAGEMENT srl
A Unit of Idex Corporation
1155495A-it,en - 24/05/07
21
• 1, 5 , 5, 10 LITERS CANISTER CLICK-OUT
1,5 , 5, 10 litres canister removal operations
(Fig.30)
A B C D
5 litres canister
(”A” – fig. 30)
1,5 litre canister
(”B” – fig. 30)
3 litres canisters
(”C” - ”D” – fig. 30)
•
If you want to remove a 5 litres canister (A) you should remove first the 3 litres canister (C)
placed immediately at its right side on the external row of canisters (fig. 15).
•
If you want to remove one of the 1,5 litres canister (B) you should remove first the 3 litres
canister (D) immediately at its right side on the external row of canisters (fig. 15).
•
After that, to remove one of the 1,5 or 5 litres canister follow the next procedure.
CLICK-OUT INTERNAL CANISTER
(Fig.31)
Turn the cut-off cock
in clockwise direction
from the open position
(see picture fig. 31)…
(Fig.32)
…to the close position
(fig. 32); in this way it
will be possible to
release the entire valve
& pump group without
any colorant leakage..
(Fig.33)
Unscrew the locking
nuts of the pump
(fig. 33)
(Fig.34)
and keep out the entire
pump & valve group
(fig. 34).