INTERNAL CANISTERS CLICK-OUT
• 3 = 3 litres canisters (External).
• 5 = 5 litres canisters (Internal).
• 10 = 10 litres canisters (Internal).
•
If you want to remove a internal canister you should have to remove first the external canister
positioned immediately at its right side.
•
After that, to remove one of the internal canisters follow the next procedure.
10
10
5
5
5
5
3
3
3
5
5
3
3
3
3
(Fig.14)
Turn the cut-off cock
in clockwise direction
from the open
position (see picture
fig.14)…
(Fig.15)
…to the close position
(fig.15); in this way it
will be possible to
release the entire
valve & pump group
without any colorant
leakage.
(Fig.16)
Unscrew the locking
nuts of the pump
(fig. 16)
(Fig.17)
and keep out the entire
pump & valve group
(fig.17).