Bird Technologies 8890-400 Series Manuale d'uso
Pagina 4

CAUTION
Caution notes call attention to a procedure, which if not correctly
performed, could result in damage to the instrument.
This symbol appears on the equipment indicating there is
important information in the instruction manual regarding
that particular area.
+
Note: Calls attention to supplemental informa-
tion
Warning Statements
The following safety warnings appear in the text where there is danger to op-
erating and maintenance personnel and are repeated here for emphasis.
WARNING
Before placing the unit into operation, remove the shipping plug at the
top of radiator, near front, substitute with the specially shielded
breather plug. Use a 3/4 inch flat wrench for this purpose - do not lose
the O-Ring Seal.
This vent hole must remain open at all times when the unit is in
operation or cooling. Failure to do this could result in damage to the
equipment and endanger the operator’s safety. The use of the vent plug
also protects the filler opening against intrusion of foreign material
while allowing unobstructed venting of the tank. The shipping plug
(with O-Ring seal) should be put back in place whenever the unit is to
be transported. Be sure to check this plug.
WARNING
Never attempt to disconnect RF equipment from the transmission line
while RF power is being applied. Leaking RF energy is a potential
health hazard.
Caution Statement
The following equipment caution appears in the text whenever the equipment
is in danger of damage and is repeated here for emphasis.
CAUTION
This unit is factory filled with approximately 2.9 gallons (11 liter) of a
specially selected dielectric fluid, P/N 5-1070-3. No other coolant should
be used.
ii