Timer Fail
Timer refresh failure.
E2018
Prog Timer
Programmable interval timer error.
E2019
Parity Error
Parity error.
E201A
SIO Err
SIO failure.
E201B
Kybd Controller
Keyboard controller failure.
E201C
SMI Init
System management interrupt (SMI) initialization failure.
E201D
Shutdown Test
BIOS shutdown test failure.
E201E
POST Mem Test
BIOS POST memory test failure.
E201F
DRAC Config
Dell remote access controller (DRAC) configuration failure.
E2020
CPU Config
CPU configuration failure.
E2021
Memory Population
Incorrect memory configuration. Memory population order
incorrect.
E2022
POST Fail
General failure after video.
E2110
MBE Crd # DIMM ## &
##
One of the DIMMs in the set implicated by "## & ##" has had a
memory multi-bit error (MBE). If no memory card is present,
the "Crd #" string is left out of the message.
E2111
SBE Log Disable Crd #
DIMM ##
The system BIOS has disabled memory single-bit error (SBE)
logging, and will not resume logging further SBEs until the
system is rebooted. "##" represents the DIMM implicated by the
BIOS. If no memory riser card is present, the "Crd #" string is
left out of the message.
E2112
Mem Spare Crd # DIMM
##
The system BIOS has spared the memory because it has
determined that the memory had too many errors. "## & ##"
represents the DIMM pair implicated by the BIOS. If no
memory card is present, the "Crd #" string is left out of the
message.
E2113
Mem Mirror Crd # DIMM
## & ##
The system BIOS has disabled memory mirroring because it has
determined that one half of the mirror has had too many errors.
"## & ##" represents the DIMM pair implicated by the BIOS. If
no memory card is present, the "Crd #" string is left out of the
message.
E2118
Fatal NB Mem CRC
One of the connections in the Fully Buffered DIMM (FBD)
memory subsystem link on the Northbound side has failed.
E2119
Fatal SB Mem CRC
One of the connections in the FBD memory subsystem link on
the Southbound side has failed.
I1910
Intrusion
System cover has been removed.
I1911
>3 ERRs Chk Log
LCD overflow message.
A maximum of three error messages can display sequentially on
the LCD. The fourth message displays as the standard overflow
message.
I1912
SEL Full
System Event Log is full of events, and is unable to log any
more events.
W1228
ROMB Batt < 24hr
Warns predictively that the RAID battery has less than 24 hours
of charge left.