Burner and nozzle specifications – Hotpoint Ariston PY 640 T (IX)-HA Manuale d'uso
Pagina 16
Advertising

GB
16
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
100
75
55
130
0.70
0.40
0.40
1.50
2.60
1.65
1.00
3.30
39
28
28
61
80
64
50
91
189
120
73
240
186
118
71
236
2.60
1.65
1.00
3.60
110 (Y)
96
79
145 (H1)
248
157
95
343
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
(Reduced)
Thermal
power
kW
(p.c.s.*)
(Nominal)
Thermal
power
kW
(p.c.s.*)
(Nominal)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
***
**
Flow*
(g/h)
Flow*
(g/h)
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/kg.
***
Butane
P.C.S. = 49.47 MJ/kg.
Natural
P.C.S. = 37.78 MJ/m
3
RR
A
S
TC
TC
PY 640 T /HA
Advertising