10 Appendice
VEGASON 61 • Profibus PA
28784-IT
-130507
Codice
di stato
Descrizione secondo norma
Profibus
Possibile causa
0 x 51
uncertain - sensor; conversion
not accurate - low limited
Valore sensore < limite inferiore
0 x 52
uncertain - sensor; conversion
not accurate - high limited
Valore sensore > limite superiore
0 x 80
good (non-cascade) - OK
OK
0 x 84
good (non-cascade) - active
block alarm
Static revision (FB, TB) changed (attiva per 10 sec. dopo la scelta
del parametro della categoria Static)
0 x 89
good (non-cascade) - active ad-
visory alarm - low limited
Lo-Alarm
0 x 8a
good (non-cascade) - active ad-
visory alarm - high limited
Hi-Alarm
0 x 8d
good (non-cascade) - active cri-
tical alarm - low limited
Lo-Lo-Alarm
0 x 8e
good (non-cascade) - active cri-
tical alarm - high limited
Hi-Hi-Alarm